Overview

Features

The Cisco® Provider Connectivity Assurance Sensor F100 (formerly Accedian Skylight Flex 100 Performance Element) is a next-generation, multiport, 100 Gigabit Ethernet platform with ultra-low-latency packet forwarding and jitter.

Designed for high-bandwidth and high-availability applications requiring MEF-type service assurance, the Provider Connectivity Assurance Sensor F100 is optimized for scalable service delivery and high-precision, granular, real-time performance monitoring. It is an ideal edge, aggregation, or External Network-to-Network Interface (ENNI) unit for demanding high-bandwidth wireless backhaul, SLA-backed business services, Ethernet wholesale, and dark fiber termination applications.

The Assurance Sensor F100 provides all the tools to establish, validate, and monitor Layer 2 and Layer 3 services in a single unit. Zero-touch provisioning and IPv4/IPv6 management make these performance elements easy and secure to deploy and manage.

Fully integrated with the Cisco Provider Connectivity Assurance platform, it supports service delivery automation and scalable, real-time metrics collection and reporting—plus actionable insights delivery and machine learning for accelerated service rollout and improved operational efficiencies.

The Assurance Sensor F100 interoperates with other Provider Connectivity Assurance Sensors to deliver a scalable end-to-end and core-to-edge performance-assured networking solution tailored to your applications.

Figure 1. Cisco Provider Connectivity Assurance Sensor F100

The following table lists the features of the Assurance Sensor F100.

Table 1. Cisco Provider Connectivity Assurance Sensor F100 Features

Feature

Description

Form factor

1RU

Rack mount

Standard 19-inch (48.3 cm) or 23-inch (58.42 cm) rack

Airflow

Front to rear

Management port

Built-in

One RJ-45 connector (10/100/1000 BASE-T)

USB port

One USB Mini-B console port (USB 2.0)

Network ports

Four QSFP28 connectors (100GBASE-R)

Auxiliary port

One SFP+ connector (10GBASE-R)

Serial console port

One RJ-45 serial connector (RS-232 or two dry contacts)

Fans

Four fans for front-to-rear cooling

The following table lists the regulation and standard compliance features of the Assurance Sensor F100.

Table 2. Regulation and Standard Compliance (Unique ID: NG100)

Feature

Description

Safety

IEC 62368-1, EN 62368-1, UL 62368-1, CSA C22.2 No. 62368-1, AS/NZS 62368.1, J62368-1, CEI EN 62368-1, DS/EN 62368-1, SASO-IEC-62368-1

EMC - Emission (Class A)

CISPR 32, IEC 61000-3-2, IEC 61000-3-3, EN 55032, EN 61000-3-2, EN 61000-3-3, 47 CFR Part 15 Subpart B, ICES-003, AS/NZS CISPR 32, VCCI-CISPR 32, KS C 9832

EMC - Immunity

CISPR 35, EN 55035, KS C 9835

Telco

NEBS Level-3: GR-63, GR-1089

Radio

ETSI EN 301 489-19, ETSI EN 303 413

Enviro

RoHS: IEC 63000:2016,EN IEC 63000:2018

Package Contents

Package contents for the Cisco Provider Connectivity Assurance Sensor F100 include the following:

  • Assurance Sensor F100 (1)

  • 19-inch bracket kit (1)

  • Cisco Provider Connectivity Assurance Sensor F100

    This document contains URLs that point to the hardware installation guide, regulatory compliance and safety information guide, warranty, and licensing pages, and a QR code that points to the management center Documentation Portal.


Note


The package can contain other ordering options.


Serial Number Locations

The Serial Number (SN) and the Media Access Control (MAC) address are located at the bottom of the Assurance Sensor F100.

Front Panel

The following figure shows the front panel features of the Assurance Sensor F100. See Front Panel LEDs for a description of the LEDs.

Figure 2. Font Panel

1

Management port

RJ-45 connector (10/100/1000 BASE-T)

2

Console / dry contacts

RJ-45 serial connector (RS-232 or 2 dry contacts)

Note

 

Cannot be used at the same time.

Caution

 

The Dry Contacts Interface is strictly Safety Extra Low Voltage (SELV).

  • PIN #1—Dry contact 1

  • PIN #2—Not connected

  • PIN #3—RS-232 TX data

  • PIN #4—Ground

  • PIN #5—Ground

  • PIN #6—RS-232 RX data

  • PIN #7—Not connected

  • PIN #8—Dry contact 2

3

Console port

USB Mini-B port (USB 2.0)

4

RST

System reset button

Note

 

Press the RST button for more than five seconds to reset the unit to factory defaults.

Warning

 

Service-affecting

5

Network ports

Four QSFP28 connectors (100GBASE-R)

6

Auxiliary port

SFP+ connector (10GBASE-R)

7

Synchronization module (optional)

Warning

 

Ensure the unit's power source(s) have been turned off before servicing. Installations where a unit with the GNSS may be exposed to voltage in excess of 10kV, additional measures such as external surge suppressor may be necessary.

  • One SMA, GNSS antenna input

  • One SMA, sync IN

  • One SMA, sync OUT

8

Power modules

Hot-swappable input power modules (AC or DC)

Front Panel LEDs

The following figure shows the front panel LEDs and describes their states.

Figure 3. Front Panel LEDs and Their States

1

MIN MAJ CRIT LEDs

  • MIN

    Yellow—A minor alarm condition is present.

  • MAJ

    Red—A major alarm condition is present.

  • CRIT

    Red—A critical alarm condition is present.

2

Status LED

  • Green—Normal operation.

  • Green, flashing—The unit is booting.

3

Link LED

  • Off—Link is inactive.

  • Green—Link is active.

4

Activity LED

  • Off—No TX/RX activity.

  • Green, flashing—Port is receiving/transmitting data.

5

Synchronization Module LEDs

PWR

  • Off—The device is unpowered.

  • Green—The device is powered.

ANT

  • Green—GNSS is enabled and is locked on satellite.

  • Green, flashing—GNSS is enabled and searching for satellite.

SYNC IN

  • Off—No synchronization input detected.

  • Green—Synchronization input detected.

SYNC OUT

  • Off—Synchronization output deactivated.

  • Green—Synchronization output activated.

ALM

  • Off—No synchronization module alarm condition.

  • Red—Synchronization module alarm condition.

6

AC Power Supply Unit LED

  • Off—No AC power to all PSU.

  • 0.5 Hz Red, flashing—No AC power to this PSU only.

  • 1 Hz Green, flashing— AC present/only standby output on.

  • Green—Power supply AC output ON and OK.

  • Red—Power supply failure.

  • 0.5 Hz Red/green, flashing—Power supply warning.

7

DC Power Supply Unit LED

  • Off—No DC power to all PSU.

  • 0.5 Hz Red, flashing— No DC power to this PSU only.

  • 1 Hz Blue, flashing— AC present/only standby output on.

  • Blue—Power supply DC output ON and OK.

  • Red—Power supply failure.

  • 0.5 Hz Red/blue, flashing—Power supply warning.

Rear Panel

The following figure shows the rear panel of the Assurance Sensor F100.

Figure 4. Rear Panel

1

Power supply airflow outtake

Air is exhausted through the back of the power supply

2

Ground lugs

Unit protective ground point

3

System fans

Fans 1 and 2 locations

4

System fans

Fans 3 and 4 locations

Power Supply

The following table lists the specifications for each power supply used in the Assurance Sensor F100.

Table 3. Power Specifications

Description

Specification

Input power ratings

AC input: 100 to 240 V rms, 2.5 to 1.0 A, 80 Plus Platinum

DC input: V DC = 36 to 72 V DC, 6.5 to 3.25 A, Efficiency 80% (Min)@48 V

Power consumption

150 WNom, 230 WMax

Optical port power ratings

QSFP: 5.0 WMax per port

SFP+: 2.0 WMax per port

Hardware Specifications

The following table contains hardware specifications for the Assurance Sensor F100.

Dimensions (H x W x D)

1.74 x 16.8 x 13.83 inches (4.42 x 42.66 x 35.13 cm)

Weight

14.3 lb (6.5 kg)

Temperature

Operating: 32 to 122°F (0 to 50°C)

Storage: -40 to 158°F (-40 to 70°C)

Humidity

Operating: 5 to 85% RH, noncondensing

Storage: 5 to 95% RH, noncondensing

Altitude

Maximum: 6600 ft (2000 m), above sea level

Product ID Numbers

The following table lists the field-replaceable PID associated with the Assurance Sensor F100. If any internal components fail, you must get a return material authorization (RMA). See the Cisco Returns Portal for more information.

Table 4. Cisco Provider Connectivity Assurance Sensor F100 PID

PID

Description

SKY-F100-AC-DC

Provider Connectivity Assurance Sensor F100 Quad 100Gbe Ports (QSFP28), without PSU

Power Cord Specifications

Each AC power input requires a separate power cord. Power cords are available for connection to the Assurance Sensor F100.

If you do not order the optional power cord with the system, you are responsible for selecting the appropriate power cord for the product. Using a incompatible power cord with this product may result in electrical safety hazard.

PID

Description

SKY-PC-F-NA

Power Cord US/CA, NEMA 5-15P to C13, 10 A/125 V, Black, 1.8 m

SKY-PC-F-EUR

Power Cord EU, CEE 7/7 to C13, 10 A/250 V, Black, 2.5 m

SKY-PC-F-UK

Power Cord UK/SG, BS 1363A to C13, 10 A/250 V, Black, 2.5 m

SKY-PC-F-JPN

Power Cord JP, JIS 8303 to C13, 15 A/125 V, Black, 1.8 m

SKY-PC-F-IND

Power Cord IN, IS 1293 to C13, 10 A/250 V, Black, 2.0 m

SKY-PC-F-AUS

Power Cord AS/NZ, AS/NZS 4417 to C13, 10 A/250 V, Black, 2.5 m

SKY-PC-F-SWI

Power Cord SZ, SEV 1011 to C13, 10 A/250 V, Black, 2.5 m

SKY-PC-F-ITA

Power Cord IT, CEI 23-16 to C13, 10 A/250 V, Black, 2.5 m

SKY-PC-F-ISR

Power Cord IL, SI 32 to C13, 10 A/250 V, Black, 2.5 m

SKY-PC-F-TWN

Power Cord TW, NEMA 5-15P to C13, 10 A/125 V, Black, 1.8 m

SKY-PC-F-ARG

Power Cord AR, IRAM 2073:2009 to C13, 10 A/250 V, Black, 2.5 m

SKY-PC-F-BRZ

Power Cord BR, NBR 14136 to C13, 10 A/250 V, Black, 2.5 m

SKY-PC-F-CHN

Power Cord CN, GB 15934-2008 to C13, 10 A/250 V, Black, 2.5 m

SKY-PC-F-C14

Power Cord US/CA/AS/NZ/TW/CN, C14 to C13, 10 A/125 V, Black, 2.0 m

Note