Card Protection for T3 or E3 Interface Module
The Card Protection feature is introduced for the 48-port T3 or E3 interface module. In this feature, the interface module bay is protected by another interface module of the same type.
Card Protection
The Card Protection feature is required to protect traffic flow either when an interface module is out of service, when the software fails or a hardware component has issues. Because card protection is supported only on redundant interface modules, traffic is switched to the protect interface module when the active interface module does not respond, and vice-versa.
Note |
This feature does not require any change in the patch panel of the interface modules. |
To support the Card Protection feature, the configuration on the active and protect interface module must be same. To achieve this, a virtual interface module is created with the same interface module type as the active interface module. A virtual controller is also created, which broadcasts the configuration to both the interface modules. The configuration on the physical controllers is then blocked and you can make configuration changes only on the virtual controller. The user configuration can only be performed on the virtual controller.
The virtual controller supports CEM level configuration and all other configurations. These configurations are blocked on physical controllers.
Note |
DS3 (T3) channelized into T1 and E3 channelized into E1s are supported in card protection. For more information on configuration, see the Configuring the Controller of Channelized T3/T1 Interfaces section. |
Y Cable
In card protection, a Y cable is used to multiplex the signal from the patch panel to both the ports of active and standby interface modules. Both the active and protect ports receive the signal, but only the active port transmits the signal from its port. Protect port transmitter is disabled.
Card Protection Switchover
The following table shows the card protection switchover trigger and time to complete the switchover between the working and protect interface module.
Trigger |
Time |
---|---|
Interface Module Reload with CLI OIR |
Less than 50 millisecond |
Non-responsive Interface Module Process (interface module reloads on its own, the reload is initiated due to software error) |
100 millisecond to 200 millisecond |
Interface Module shuts down due to high temperature |
Less than 50 millisecond |
Interface Module shuts down using CLI |
Less than 50 millisecond |
Interface Module stops using CLI |
Less than 50 millisecond |
Serializer/Deserializer (SerDes) Failures |
250 millisecond to 1 second |
Alarm Based Switchover |
Based on Hold Over Time or Soak Time |
Card Protection Commands |
20 millisecond to 30 millisecond |
Non-responsive Interface Module Process (interface module reloads on its own, the reload is initiated due to software error) |
200 millisecond to 1 second |
Card Physical Jackout |
200 millisecond to 1 second |
Alarm Based Switchover
Alarm based switchover is only applicable for Loss Of Signal (LOS) alarm. Switchover happens only when the number of ports with LOS alarm in working interface module is greater than that on the protect interface module.
Each card protection group maintains a weight for each working and protect interface module. This weight is updated when the LOS alarms are asserted or cleared. The switchover happens only if the weight of working interface module and protect interface module stays same for a certain amount of time called soak time.
When there is any issue with the Patch Panel, both working interface module and protect interface module have the same number of LOS alarms (weights are same). Hence, switchover does not happen.
Guidelines on Alarm Based Switchover Scenarios
Considerations for Hold-Off Timer
-
With card-protection where Y-cable is used for connecting the protected cards, if Signal Failure (SF) or Signal Degrade (SD) is observed on any of the ports of these protected cards, LOS alarms will be raised on those respective ports. In rare scenarios, these SF/SD notifications across the ports could vary in duration for reporting the LOS alarms due to environment conditions. Hence, to avoid multiple switching between the protected IMs in these scenarios, hold-off timer is introduced to hold the switchover notification till the LOS alarm notification is synchronized on both the IMs.
-
Hold-ff timer can be configured using the hold-off timer seconds CLI command. By Default, (and recommended value for) the hold-off timer value is enabled for 5 seconds.
-
When LOS alarms are detected on the ports of the protected IMs, the number of alarm occurrence is compared between the active and standby IM. If the active card has more LOS Alarms, then the hold-off timer gets initiated. After the hold-off timer expiry (5 sec in default case), a protection switch will be triggered to the card having lesser number of alarm notifications.
-
If the hold-off timer is set to zero, then the switchover is triggered immediately when the weightage of alarm occurrence in active is more than the standby. Note that in this scenario, it could also lead to multiple protection switching between the IMs till the LOS alarms are settled on all the failed ports of both the IMs.
Considerations for Router Bring up or IM OIR
-
During the router bring up or reboot or with Reboot and IM Online Insertion and Removal (OIR), once the IMs are online, there will be alarms flooded to software for all the ports from both the active and standby cards.
-
NO operational events or switchover events to be performed during this time, and to allow the alarms on both the IM to be settled. (The approximate recommended duration is 1 minute).
Restrictions
-
Card physical jack out convergence time for card protection switchover is more than 50 milliseconds.
-
The time taken to restart the interface module due to any software error is more than 50 milliseconds.
-
Alarm toggle on active or backup card causes at least one card protection switch.
-
When BERT is started from the virtual controllers, the syslog displays the physical controllers instead of the virtual controller port.
Supported Features on Interface Module
The supported features are:
-
Switching Mode
-
Non-revertive mode
-
Revertive mode
-
-
Alarm Based Switchover
-
SerDes Based Switchover
-
Adaptive Clock Recovery (ACR) on virtual CEM
-
Differential Clock Recovery (DCR) on virtual CEM
-
Maintenance Commands
-
Lockout
-
Force
-
Manual
-
Note |
All controller configurations are performed on the virtual controller. |
You can create card protection with one slot (either primary or backup) and the remaining slots can be added later.
How to Configure Card Protection for T3 or E3
Configuring T3/E3 Card Protection
Pre-requisites
The interface module should be free from any configuration.
Configuring Card Protection Group:
enable
configure terminal
card-protection [1-16]
primary slot 0 bay 0
backup slot 0 bay 5
end
Note |
The card protection number 1 to 16 refers to the Card Protection Group Number (CPGN). |
Note |
This is a non-revertive mode. |
Configuring Virtual Card and Virtual Controller:
When card protection group is configured, it creates virtual card for card protection object, denoted by 8/x/port. Slot 8 is a fixed slot number for all card protection-created virtual card. Bay number ‘x’ is derived from the CPGN, where x=CPGN-1. Since card protection group number ranges from 1 to16, bay number ranges from 0 to 15. Virtual controllers can be configured from 8/x/0 to 8/x/47.
Physical Card Configuration:
Configures mode T3/E3 on physical controllers of both primary (0/0) and backup (0/5) card.
enable
configure terminal
controller mediatype 8/0/0
mode t3
end
Virtual Card Configuration:
-
Configures mode T3/E3 on virtual controllers.
-
Configures CEM on virtual controller (8/x/port).
-
Configures xconnect and local connect on CEM interface.
enable
configure terminal
controller t3 8/0/0
cem 0 unframed
interface cem 8/0/0
cem 0
xconnect 10.1.1.1 112 encasulation mpls
end
Note |
This is a non-revertive mode. |
Note |
To un-configure a CEM group under a virtual controller, first perform shutdown of the virtual controller and then un-configure the CEM group. |
Configuring Revertive Mode
To configure revertive mode:
enable
configure terminal
card-protection 4
primary slot 0 bay 0
backup slot 0 bay 5
end
card-protection 4
revertive time [30-720]
end
Note |
The revertive time ranges from 30 to 720 seconds. |
Verifying T3/E3 Card Protection Configuration
Use show card-protection detail command to verify card protection group configuration.
#show card-protection 2 detail
Working(0/1:A900-IMA48T-C NCS4200-48T3E3-CE):
Number of LOS Alarms:7
ok,Active
1:1, Revertive
Protect(0/2:A900-IMA48T-C NCS4200-48T3E3-CE):
Number of LOS Alarms:7
ok,Inactive
1:1, Revertive
Revert Timer : (Not Started)
Last switchover reason :None
#show card-protection 4
CPGN Primary Card Backup Card Active
-------------------------------------------------------------------------------
4 0/1 0/2 Primary
#show running-configuration | b 8/0/
controller mediatype 8/0/0
!
controller mediatye 8/0/1
!
controller mediatype 8/0/2
#
Use show xconnect all command to verify xconnect configuration.
#show xconnect all
XC ST=Xconnect State S1=Segment1 State S2=Segment2 State
UP=Up DN=Down AD=Admin Down IA=Inactive
SB=Standby HS=Hot Standby RV=Recovering NH=No Hardware
XC ST Segment 1 S1 Segment 2 S2
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
UP pri ac CE8/0/0:0(SATOP T3) UP mpls 10.1.1.1:112 UP
#
Configuring Maintenance Commands
To configure maintenance commands:
enable
configure terminal
card-protection 4
primary slot 0 bay 0
backup slot 0 bay 5
end
card-protection 4
card-protection [manual {backup|primary} | force {backup|primary} | lockout]
end
Note |
Maintenance commands are not synced in the standby environment. After Redundancy Force Switchover (SSO), maintenance commands must be executed again on the new active environment. |
Priority Table
The following table shows the priority of the actions:
Priority |
Configurations |
---|---|
1 |
Lockout |
2 |
Force |
3 |
Alarm or Card Failure |
4 |
Manual Switch |
5 |
Revert |
Associated Commands
The following table shows the commands for the IM configuration:
Command |
Link |
---|---|
Card Protection Creation Commands: card-protection CPGN card-protection {primary | backup} card-protection revertive time Card Protection Maintenance Commands: card-protection CPGN [manual {primary | backup} | force {primary | backup} | lockout ] |
|
show card-protection CPGN detail |