Troubleshooting

This chapter provides information about troubleshooting issues, if any, on the device:

Pinouts

The following sections describe the pinouts for the device interfaces:

BITS Port Pinouts

The following table summarizes the BITS port pinouts.

Table 1. BITS Port Pinouts

Pin

Signal Name

Direction

Description

1

RX Ring

Input

Receive Ring

2

RX Tip

Input

Receive Tip

3

Not used

4

TX Ring

Output

TX Ring

5

TX Tip

Output

TX Tip

6

Not used

7

Not used

8

Not used

Time-of-Day Port Pinouts

The following table summarizes the ToD/1-PPS port pinouts.

Table 2. RJ-45 1PPS/ToD Port Pinouts

Pin

Signal Name

Direction

Description

1

RESERVED

Output

Do Not Connect

2

RESERVED

Input

Do Not Connect

3

1PPS_N

Output or Input

1PPS RS422 signal

4

GND

5

GND

6

1PPS_P

Output or Input

1PPS RS422 signal

7

TOD_N

Output or Input

Time-of-Day character

8

TOD_P

Output or Input

Time-of-Day character

Alarm Port Pinouts

The following table summarizes the external alarm input pinouts.

Table 3. External Alarm Input Pinouts

Pin

Signal Name

Description

1

ALARM0_IN

Alarm input 0

2

ALARM1_IN

Alarm input 1

3

No connect

4

ALARM2_IN

Alarm input 2

5

ALARM3_IN

Alarm input 3

6

No connect

7

No connect

8

COMMON

Alarm common

Management Ethernet Port Pinouts

The following table summarizes the Management Ethernet port pinouts.

Table 4. Fan Alarm Port Pinout

Pin

Signal Name

1

TRP0+

2

TRP0-

3

TRP1+

4

TRP2+

5

TRP2-

6

TRP1-

7

TRP3+

8

TRP3-

USB Console Port Pinouts

The table below summarizes the USB console port pinouts.

Table 5. Single USB Console Port Pinouts

Pin

Signal Name

Description

A1

Vcc

+5VDC

A2

D-

Data -

A3

D+

Data +

A4

Gnd

Ground


Note


The USB console port +5VDC is input, and operates as an USB peripheral device.

USB Flash or MEM Port Pinouts

The table below summarizes the USB flash or MEM port pinouts.

Table 6. Single USB Flash or MEM Port Pinouts

Pin

Signal Name

Description

A1

Vcc

+5VDC (500mA)

A2

D-

Data -

A3

D+

Data +

A4

Gnd

Ground


Note


USB TYPE-A receptacle is used.

Note


The USB flash or MEM port +5VDC is output. Cisco ASR 920 Series Aggregation Services Router provides power for USB flash or MEM port. This port operates as a USB host device.

Check Optical Fiber Specifications

Optical fiber transmission defines two types of fiber specification:

  • Single mode with three transmission types: short reach, intermediate reach, and long reach.

  • Multimode with only short reach.

Check Alarm Conditions

The following table summarizes the meaning of alarm conditions on the device.

Table 7. Alarm Conditions Summary

Alarm Type

Alarm Meaning

Critical

Port in down state.

Environmental sensor threshold exceeded critical level (voltage, temperature).

Major

Environmental sensor threshold exceeded major level (voltage, temperature).

Info

Port is administratively shut down.