Specifications

Environmental Specifications

Table 1. Environmental Specifications

Specification

Value

Operating Temperature

–40º C to 65º C

Note

 
The temperature range will vary for supported SFP/SFP+ installed on the router. See the corresponding SFP/SFP+ documentation for more details.

Nonoperational temperature

40 to 158°F (-40 to 70°C)

Non-operational temperature (Transportation or Storage, or both)

-40°F (-40°C) for 72 hrs

158°F (70°C) for 72 hrs

Section 4.1.1.1 of GR-63 or Section 9.1 of ATIS-0600010.2007

104°F (40°C) and 95% RH for 96 hrs

Section 4.1.1.3 of GR-63 or Section 9.3 of ATIS-0600010.2007

Operational humidity

5% to 95%, RH condensing (GR-3108, Class 3)

Non-operational humidity

5% to 95% RH

Non-operational altitude

15000 ft

Operational mechanical shock

Acceleration half sine 50 m/s^2, for 11msec. 100 shocks/surface (EN 300 019-2-4 V2.3.1)

Non-operational mechanical shock

Acceleration half sine 180 m/s^2, for 6msec. 100 shocks/surface. (EN 300 019-2-2 V2.3.1)

Operational vibration

2.5-200 Hz with spectral break point of 0.1 [(m/s²)²]/Hz (0.001 g²/Hz) at 2.5 - 5 Hz 6 db/octave and 100-200 Hz at -24 db/octave. (EN 300 019-2-4 V2.3.1)

Non-operational vibration

5-200 Hz with spectral break point of 1.0 [(m/s²)²]/Hz (0.01 g²/Hz) at 5 - 100 Hz -6 db/octave and 20-200 Hz at -24 db/octave. (EN 300 019-2-2 V2.3.1)

Cold start

-40°F (-40°C)

Hot start

149°F (65° C)

Non-operational Free-Fall Drop

Drop the unpackaged sample 3.9" onto a rigid surface. Drop 1 face, 2 edges, and 2 corners. (ENG-339611.Rev2 [Test Method: IEC-68-2-32])

Earthquake, Zone 4

Equipment complies with earthquake tests per sections 4.4.1 and 5.4.1 of GR-63 or ANSI TI-329 (GR-3108 Class 3)