Prerequisites and Guidelines
Note |
If you are already running Nexus Dashboard with Fabric Controller service, skip this section and upgrade as described in Upgrading Existing ND Cluster to This Release instead. |
Upgrading from DCNM 11.5(4) consists of the following workflow:
-
Ensure you complete the prerequisites and guidelines described in this section.
-
Back up your existing configuration using a migration tool specific to the target NDFC release.
-
Deploy a brand new Nexus Dashboard cluster with Fabric Controller (NDFC) service.
Note that unlike in previous releases where you had to install the service and enable it after the cluster was already deployed, in this release you enable the service during initial cluster deployment due to the introduction of the unified installation.
-
Restore the configuration backup you created in step 1.
Note |
Before you proceed with the upgrade, validate each fabric's credentials. For LAN fabrics, navigate to the Validate to validate credentials. page, select each fabric, and chooseFor SAN fabrics, navigate to the Validate to validate credentials. page, select each fabric, and choose |
Persona Compatibility
By using the appropriate Upgrade Tool, you can restore data that is backed up from DCNM Release 11.5(4) on a newly deployed Nexus Dashboard Fabric Controller for the personas as mentioned in the following table:
Backup from DCNM 11.5(4) | Persona Enabled in NDFC After Upgrade |
---|---|
DCNM 11.5(4) LAN Fabric Deployment on OVA/ISO/SE | Fabric Controller + Fabric Builder |
DCNM 11.5(4) PMN Deployment on OVA/ISO/SE | Fabric Controller + IP Fabric for Media (IPFM) |
DCNM 11.5(4) SAN Deployment on OVA/ISO/SE | SAN Controller |
DCNM 11.5(4) SAN Deployment on Linux | SAN Controller |
DCNM 11.5(4) SAN Deployment on Windows | SAN Controller |
Feature Compatibility Post Upgrade
The following table lists caveats associated with features that are restored from DCNM 11.5(4) backup after upgrading.
Note |
SAN Insights and VMM Visualizer features are not enabled after restore; you can choose to enable them in the page of the Nexus Dashboard Fabric Controller UI. |
Feature in DCNM 11.5(4) |
Upgrade Support |
---|---|
Nexus Dashboard Insights configured Refer to Cisco Nexus Dashboard User Guide for more information. |
Supported |
Container Orchestrator (K8s) Visualizer |
Supported |
VMM Visibility with vCenter |
Supported |
Nexus Dashboard Orchestrator configured |
Not Supported |
Preview features configured |
Not supported |
LAN switches in SAN installations |
Not supported |
Switches discovered over IPv6 |
Not supported |
DCNM Tracker |
Not supported |
Fabric Backups |
Not supported |
Report Definitions and Reports |
Not supported |
Switch images and Image Management policies |
Not supported |
SAN CLI templates |
Not carried over from 11.5(4) |
Switch images/Image Management data |
Not carried over from 11.5(4) |
Slow drain data |
Not carried over from 11.5(4) |
Infoblox configuration |
Not carried over from 11.5(4) |
Endpoint Locator configuration |
You must reconfigure Endpoint Locator (EPL) post upgrade. However, historical data is retained up to a maximum size of 500 MB. |
Alarm Policy configuration |
Not carried over from 11.5(4) |
Performance Management data |
CPU/Memory/Interface statistics up to 90 days is restored post upgrade. |
Temperature data |
Temperature data is not saved in the backup and as a result is not restored after the migration. You must re-enable temperature data collection after the migration. |