show controllers e1命令會顯示控制器硬體特定的控制器狀態。它顯示的資訊對於診斷任務通常很有用。
本文件沒有特定需求。
本文件所述內容不限於特定軟體和硬體版本。
如需文件慣例的詳細資訊,請參閱思科技術提示慣例。
為了解釋使用show controllers e1命令時生成的資訊,我們來看一些輸出示例:
Bru#show controllers e1 E1 0 is up. Applique type is Channelized E1 - balanced No alarms detected. Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2 Manufacture Cookie is not programmed. Framing is CRC4, Line Code is HDB3, Clock Source is Line Primary. Data in current interval (251 seconds elapsed): 0 Line Code Violations, 0 Path Code Violations 0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs Total Data (last 24 hours) 0 Line Code Violations, 0 Path Code Violations, 0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins, 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs E1 1 is down. Applique type is Channelized E1 - balanced Transmitter is sending remote alarm. Receiver has loss of signal. Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2 Manufacture Cookie is not programmed. Framing is CRC4, Line Code is HDB3, Clock Source is Line Secondary. Data in current interval (200 seconds elapsed): 0 Line Code Violations, 0 Path Code Violations 0 Slip Secs, 200 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 200 Unavail Secs Total Data (last 24 hours) 0 Line Code Violations, 0 Path Code Violations, 0 Slip Secs, 86400 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins, 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 86400 Unavail Secs E1 2 is administratively down. Applique type is Channelized E1 - balanced Transmitter is sending remote alarm. Receiver has loss of signal. Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2 Manufacture Cookie is not programmed. Framing is CRC4, Line Code is HDB3, Clock Source is Internal. Data in current interval (249 seconds elapsed): 0 Line Code Violations, 0 Path Code Violations 0 Slip Secs, 249 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 249 Unavail Secs Total Data (last 24 hours) 0 Line Code Violations, 0 Path Code Violations, 0 Slip Secs, 86400 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins, 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 86400 Unavail Secs
讓我們看一下此輸出中所示的資料的含義。下表說明了每個欄位及其定義:
欄位 | 說明 |
---|---|
E1 0已啟動 | 顯示E1控制器0正在運行。控制器的狀態可以是up、down或administratively down。環回條件顯示為本地環回或遠端環回。 |
應用型別 | 顯示硬體應用型別,並指示其平衡或不平衡。 |
成幀 | 顯示當前成幀型別。E1的預設成幀是循環冗餘檢查4(CRC4)。 |
線路代碼 | 顯示當前行代碼。E1的預設線路編碼為HDB3。 |
未檢測到警報 | 此處將顯示控制器檢測到的任何警報。可能的警報有:
|
當前間隔中的資料(經過251秒) | 顯示當前累積週期,每隔15分鐘滾動到24小時累積中。累積週期為1到900秒。最舊的15分鐘時間段從24小時累積緩衝區的後面跌落。 |
線路代碼違規 | 指示出現雙極違規(BPV)或過多的零(EXZ)錯誤事件。 |
路徑代碼衝突 | 表示D4和E1-no CRC格式的幀同步位錯誤,或者擴展超幀(ESF)和E1-CRC格式的CRC錯誤。 |
滑動秒 | 表示複製或刪除國內中繼介面(DS1)幀的負載位。當同步接收終端的定時和接收的訊號之間存在差時,可能發生滑動。 |
損失秒 | 指示檢測到幀外(OOF)錯誤的秒數。 |
線路錯誤秒數 | 線路錯誤秒(LES)是偵測到一個或多個線路代碼違規錯誤的秒數。 |
降級分鐘數 | 降級分鐘是估計錯誤率超過1E-6但不超過1E-3的分鐘。 |
錯誤秒 | 在ESF和E1 CRC鏈路中,錯誤秒是指檢測到以下缺陷之一的第二秒:
|
突發錯誤秒 | 第二個路徑編碼違規錯誤多於一個但少於320個,沒有嚴重誤碼幀缺陷以及沒有檢測到傳入的AIS缺陷。此引數中不包括受控滑塊。 |
嚴重錯誤秒 | 對於ESF訊號,這是第二次檢測到以下缺陷之一:
|
無用秒 | 介面上的總秒數。通過計算介面不可用的秒數來計算此欄位。 |