Introduction
Este documento descreve como solucionar problemas de VLANs suspensas devido a falha na alocação Light Distribution Box (LDB) ao usar o extensor de estrutura (FEX) com placas-mãe M1 em um switch Nexus 7000 Series.
Prerequisites
Requirements
Não existem requisitos específicos para este documento.
Componentes Utilizados
As informações neste documento são baseadas nestas versões de software e hardware:
- Cisco NX-OS versão 6.2(x)
- Switch Cisco Nexus 7000 Series
- Extensor de estrutura Cisco Nexus 2000 Series
The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.
Informações de Apoio
LDB é uma tabela de hardware que armazena propriedades para quadros recebidos pelo mecanismo de encaminhamento, incluindo mapeamento de tronco para vlan para canais de porta FEX. Falha na alocação de LDB indica que esse banco de dados foi esgotado.
Quando um módulo FEX é conectado a um N7K-M132XP-12 (não XL), o número máximo de entradas LDB é aproximadamente 228k. Com o módulo XL, o limite é aproximadamente 512K.
O total de entradas LDB é a soma dos intervalos de VLAN definidos em cada FEX HIF (diferença entre a VLAN mais alta e a mais baixa definida em um HIF).
Por exemplo:
switchport trunk allowed vlan 1-4 = 4 entradas LDB
switchport trunk allowed vlan 1-4, 70-80, 800 = 800 entradas LDB
tronco de porta de switch permitido vlan 200-800 = 600 entradas LDB
tronco de porta de switch permitido vlan 200, 800 = 600 entradas LDB
Se as portas 101/1/1 a 101/1/10 estiverem configuradas com a vlan 200 permitida pelo tronco da porta do switch, 800 o número total de entradas LDB consumidas seria 6000 (10x600).
As portas de acesso consomem 1 entrada LDB (a VLAN de acesso definida no HIF).
Verifique as entradas LDB de cada módulo usando este comando:
N7K-A# attach mod 1
Attaching to module 1 ...
To exit type 'exit', to abort type '$.'
module-1#
module-1# show system internal eltmc info ldb summary
LDB allocation summary:
Max dynamic ldb entries: 203776
Total number of entries: 199680
Number of free entries: 197
Number of free regions: 2
Number of allocated entries: 199483
Number of allocated regions: 280
Number of fail allocations: 21
[an error occurred while processing this directive]
Neste exemplo, houve 21 alocações de LDB com falha. Devido ao mecanismo de hash usado para hash entradas específicas em partes específicas do banco de dados, não é necessário que o número total de entradas atinja as entradas dinâmicas máximas de LDB para ver alocações com falhas.
Esta saída exibe o número de entradas LDB (em hexadecimal) usadas por cada canal de porta ou interface:
module-1# show system internal eltmc info ldb all
LDB allocation maps :
base size allocation
0xd400 0x1000 Shared
0xe400 0x1000 Shared
0xf400 0x1000 Shared
0x10400 0x1000 Ethernet1/4
0x11400 0x1000 Ethernet1/7
0x12400 0x1 Ethernet179/1/30
0x12401 0x1 port-channel1093
0x12402 0x1 port-channel1564
0x12403 0x1 port-channel1550
0x12404 0x1 port-channel1527
0x12405 0x1 port-channel1546
0x12426 0x1 Ethernet169/1/47
0x12427 0x1 Ethernet169/1/48
0x12428 0x1 Ethernet181/1/33
0x12429 0x1 Ethernet181/1/34
0x1242a 0x1 Ethernet163/1/4
0x1242b 0x1 Ethernet163/1/5
0x1242c 0x506 Ethernet183/1/7
0x12932 0x1 port-channel1096
0x12933 0x1 port-channel1095
0x12934 0x1 port-channel1092
0x12935 0x2c8 port-channel1084
0x12bfd 0x506 Ethernet183/1/8
0x13103 0x2c8 port-channel1086
0x133cb 0x1 port-channel1589
0x133cc 0x1 port-channel1063
0x133cd 0x1 port-channel1654
0x133ce 0x1 port-channel1652
0x133d4 0x1 port-channel1520
0x133d5 0x1 port-channel1560
0x133d6 0x1 port-channel1561
0x133d7 0x506 Ethernet167/1/4
0x138dd 0x506 Ethernet167/1/2
0x13de3 0x403 Ethernet165/1/2
0x141e6 0x403 Ethernet151/1/1
<snip>
[an error occurred while processing this directive]
Note: Os dois comandos acima fornecem valores LDB incorretos para N7K-M132XP-12 (não XL) no NX-OS 6.0.3 e 5.2.4.
O NX-OS 5.2.5 e 6.1 corrigirão isso.
Problema: a VLAN entra em estado suspenso devido à falha na alocação de LDB em um Nexus 7000 com extensores de estrutura Nexus 2000 conectados.
Sintomas:
1. Mensagem de erro em logs que indicam falha na alocação de LDB
2015 Feb 3 00:01:27.260 N7k1 %ETHPORT-5-IF_SEQ_ERROR: Error ("LDB Allocation Failed") communicating with MTS_SAP_ELTM for opcode MTS_OPC_ETHPM_PORT_LOGICAL_BRINGUP (RID_PORT: port-channel1001)
2015 Feb 3 00:01:27.261 N7k1 %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 268,1261-1262,1268 on Interface port-channel1001 are being suspended. (Reason: LDB Allocation Failed)
[an error occurred while processing this directive]
2. Conectividade perdida para vários hosts conectados ao FEX
3. A saída do comando show interface status err-vlans mostra a VLAN suspensa devido a LDB Failed Allocation
N7kA# show interface status err-vlans
--------------------------------------------------------------------------------
Port Name Err-Vlans Status
--------------------------------------------------------------------------------
Po1001 ***dcn2pclx01a** 268,1261-1262,1268 LDB Allocation
*LOG Failed
[an error occurred while processing this directive]
Solução
Essa é uma limitação de hardware associada à placa de linha, já que esse problema não é tratado por atualizações de software.
A recomendação é remover VLANs de HIF ou reduzir os intervalos de VLAN em FEX HIF para reduzir o número total de entradas LDB.
Cada instância de VLAN em cada interface consumirá entradas LDB (por exemplo, se o canal de porta 1 tiver 100 VLANs definidas e quatro portas físicas no canal de porta, o número total de entradas LDB consumidas será de 400, 100 instâncias por porta).