Introdução
Este documento descreve o uso e as limitações do adaptador CVR-QSFP-SFP10G na placa de linha C9600-LC-24C na plataforma Catalyst 9600.
Uso
A placa de linha C9600-LC-24C na plataforma C9600 tem 24 portas QSFP que suportam óptica de 40G e 100G. Não é possível inserir diretamente uma óptica de 10 Gbps ou 1 Gbps baseada em SFP nessas portas.
O adaptador CVR-QSFP-SFP10G oferece a flexibilidade de usar óptica de 10 Gbps ou 1 Gbps baseada em SFP em portas QSFP da placa de linha C9600-LC-24C na plataforma C9600.
Lista de módulos ópticos de 10 Gbps e 1 Gbps suportados com o adaptador CVR-QSFP-SFP10G
Nº do SL |
Óptica |
Velocidade |
Versão mínima do Cisco IOS® XE |
1 |
SFP-10G-SR |
10 Gbps |
16.11.1 |
2 |
SFP-10G-SR-S |
10 Gbps |
16.11.1 |
3 |
SFP-10G-LR |
10 Gbps |
16.11.1 |
4 |
SFP-10G-LR-S |
10 Gbps |
16.11.1 |
5 |
SFP-10G-ER |
10 Gbps |
16.11.1 |
6 |
SFP-10G-ER-S |
10 Gbps |
16.11.1 |
7 |
SFP-10G-ZR |
10 Gbps |
16.11.1 |
8 |
SFP-10G-ZR-S |
10 Gbps |
16.11.1 |
9 |
DWDM-SFP10G-xxx |
10 Gbps |
16.11.1 |
10 |
SFP-H10GB-CU1M |
10 Gbps |
16.11.1 |
11 |
SFP-H10GB-CU3M |
10 Gbps |
16.11.1 |
12 |
SFP-H10GB-CU5M |
10 Gbps |
16.11.1 |
13 |
GLC-T* |
1 Gbps |
16.12.2/17.1.1 |
14 |
GLC-TE* |
1 Gbps |
16.12.2/17.1.1 |
15 |
GLC-LH-SMD |
1 Gbps |
16.12.2/17.1.1 |
16 |
GLC-SX-MMD |
1 Gbps |
16.12.2/17.1.1 |
* Velocidades de 10 Mbps e 100 Mbps com GLC-T e GLC-TE não são suportadas com o adaptador CVR-QSFP-SFP10G. Somente velocidade de 1 Gbps com GLC-T e GLC-TE é suportada com o adaptador CVR-QSFP-SFP10G.
Layout e mapeamento de portas do painel frontal da placa de linha C9600-LC-24C
1/25 |
3/27 |
5/29 |
7/31 |
9/33 |
11/35 |
13/37 |
15/39 |
17/41 |
19/43 |
21/45 |
23/47 |
2/26 |
4/28 |
6/30 |
8/32 |
10/34 |
12/36 |
14/38 |
16/40 |
18/42 |
20/44 |
22/46 |
24/48 |
Essas CLIs podem ser usadas para verificar o mapeamento de portas. O modo de velocidade operacional e a numeração de porta física para virtual (para interfaces de 100 Gbps):
show hw-module subslot x/0 port-group mapping
show hw-module subslot x/0 port-group operation-mode
show hw-module subslot x/0 port-group port-number
onde x é o número do slot da placa de linha.
Saída de exemplo:
Switch#show hw-module subslot 1/0 port-group mapping
Port Group Mapping for slot 1
Port-Group Ports
1 Fo1/0/1, Fo1/0/2, Hu1/0/25
2 Fo1/0/3, Fo1/0/4, Hu1/0/27
3 Fo1/0/5, Fo1/0/6, Hu1/0/29
4 Fo1/0/7, Fo1/0/8, Hu1/0/31
5 Fo1/0/9, Fo1/0/10, Hu1/0/33
6 Fo1/0/11, Fo1/0/12, Hu1/0/35
7 Fo1/0/13, Fo1/0/14, Hu1/0/37
8 Fo1/0/15, Fo1/0/16, Hu1/0/39
9 Fo1/0/17, Fo1/0/18, Hu1/0/41
10 Fo1/0/19, Fo1/0/20, Hu1/0/43
11 Fo1/0/21, Fo1/0/22, Hu1/0/45
12 Fo1/0/23, Fo1/0/24, Hu1/0/47
Switch#show hw-module subslot 1/0 port-group operation-mode
Module 1 port group 1 is running in HundredGigabitEthernet mode
Module 1 port group 2 is running in FortyGigabitEthernet mode
Module 1 port group 3 is running in FortyGigabitEthernet mode
Module 1 port group 4 is running in FortyGigabitEthernet mode
Module 1 port group 5 is running in FortyGigabitEthernet mode
Module 1 port group 6 is running in FortyGigabitEthernet mode
Module 1 port group 7 is running in HundredGigabitEthernet mode
Module 1 port group 8 is running in HundredGigabitEthernet mode
Module 1 port group 9 is running in HundredGigabitEthernet mode
Module 1 port group 10 is running in HundredGigabitEthernet mode
Module 1 port group 11 is running in HundredGigabitEthernet mode
Module 1 port group 12 is running in HundredGigabitEthernet mode
Switch#show hw-module subslot 1/0 port-group port-numbering
Physical Port Mapping for slot 1
Physical-Port Mapped-Port
1 Hu1/0/25
2 Hu1/0/26
3 Hu1/0/27
4 Hu1/0/28
5 Hu1/0/29
6 Hu1/0/30
7 Hu1/0/31
8 Hu1/0/32
9 Hu1/0/33
10 Hu1/0/34
11 Hu1/0/35
12 Hu1/0/36
13 Hu1/0/37
14 Hu1/0/38
15 Hu1/0/39
16 Hu1/0/40
17 Hu1/0/41
18 Hu1/0/42
19 Hu1/0/43
20 Hu1/0/44
21 Hu1/0/45
22 Hu1/0/46
23 Hu1/0/47
24 Hu1/0/48
Limitações com o adaptador CVR-QSFP-SFP10G
- O adaptador CVR-QSFP-SFP10G não deve ser instalado em uma porta de número par na qual a porta de número ímpar correspondente tenha óptica de 40GE. Por exemplo, se a porta 1 tiver óptica de 40GE, CVR-QSFP-SFP10G não deverá ser instalado na porta 2.
- O adaptador CVR-QSFP-SFP10G não deve ser instalado em nenhuma porta que tenha uma configuração de ativação. Por exemplo, o adaptador CVR-QSFP-SFP10G não deve ser instalado em uma porta configurada para operar em 100GE.