The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This document describes the NetFlow templates used by the SNA Flow Sensor, this includes information regarding Enterprise-specific elements.
The NetFlow element IDs used here are standard netflow protocol, however the template information and which elements included in each template are subject to change at any time.
Tip: As of SNA version 7.3 the Flow Sensor appears to only send template IDs 335-352 by default, which are the IPFIX templates. All IPFIX templates are sent together every 60 seconds, regardless of the type of traffic seen by the monitorng port of the Flow Sensor (for example IPv4 vs IPv6).
Note: The templates with an asterisk (*) beside them contain the basic NetFlow v9/IPFIX fields found on the IANA list for standard flow creation and analysis.
IPV4_FIRST_FLOW_TEMPLATE_ID 317*
IPV4_FIRST_FLOW_DEEP_TEMPLATE_ID 318*
IPV4_FLOW_TEMPLATE_ID 319*
IPV4_EVENT_TEMPLATE_ID 320
IPV6_FIRST_FLOW_TEMPLATE_ID 321*
IPV6_FIRST_FLOW_DEEP_TEMPLATE_ID 322*
IPV6_FLOW_TEMPLATE_ID 323*
IPV6_EVENT_TEMPLATE_ID 324
IPV4_SRC_EMAIL_COUNTS_TEMPLATE_ID 325
IPV4_FIRST_FLOW_RTM_TEMPLATE_ID 326*
IPV4_FIRST_FLOW_DEEP_RTM_TEMPLATE_ID 327*
IPV4_FLOW_RTM_TEMPLATE_ID 328*
IPV6_FIRST_FLOW_RTM_TEMPLATE_ID 329*
IPV6_FIRST_FLOW_DEEP_RTM_TEMPLATE_ID 330*
IPV6_FLOW_RTM_TEMPLATE_ID 331*
IPV4_DST_EMAIL_COUNTS_TEMPLATE_ID 332
IPV6_SRC_EMAIL_COUNTS_TEMPLATE_ID 333
IPV6_DST_EMAIL_COUNTS_TEMPLATE_ID 334
IPV4_FIRST_FLOW_IPFIX_TEMPLATE_ID 335*
IPV4_FIRST_FLOW_DEEP_IPFIX_TEMPLATE_ID 336*
IPV4_FLOW_IPFIX_TEMPLATE_ID 337*
IPV4_EVENT_IPFIX_TEMPLATE_ID 338
IPV6_FIRST_FLOW_IPFIX_TEMPLATE_ID 339*
IPV6_FIRST_FLOW_DEEP_IPFIX_TEMPLATE_ID 340*
IPV6_FLOW_IPFIX_TEMPLATE_ID 341*
IPV6_EVENT_IPFIX_TEMPLATE_ID 342
IPV4_SRC_EMAIL_COUNTS_IPFIX_TEMPLATE_ID 343
IPV4_FIRST_FLOW_RTM_IPFIX_TEMPLATE_ID 344*
IPV4_FIRST_FLOW_DEEP_RTM_IPFIX_TEMPLATE_ID 345*
IPV4_FLOW_RTM_IPFIX_TEMPLATE_ID 346*
IPV6_FIRST_FLOW_RTM_IPFIX_TEMPLATE_ID 347*
IPV6_FIRST_FLOW_DEEP_RTM_IPFIX_TEMPLATE_ID 348*
IPV6_FLOW_RTM_IPFIX_TEMPLATE_ID 349*
IPV4_DST_EMAIL_COUNTS_IPFIX_TEMPLATE_ID 350
IPV6_SRC_EMAIL_COUNTS_IPFIX_TEMPLATE_ID 351
IPV6_DST_EMAIL_COUNTS_IPFIX_TEMPLATE_ID 352
IPV4_ETTA_IDP_TEMPLATE_ID 353
IPV4_ETTA_IDP_IPFIX_TEMPLATE_ID 354
IPV4_ETTA_SPLT_TEMPLATE_ID 355
IPV4_ETTA_SPLT_IPFIX_TEMPLATE_ID 356
IPV4_ETTA_BD_TEMPLATE_ID 357
IPV4_ETTA_BD_IPFIX_TEMPLATE_ID 358
IPV4_ETTA_TLS_TEMPLATE_ID 359
IPV4_ETTA_TLS_IPFIX_TEMPLATE_ID 360
IPV4_ETTA_SALT_TEMPLATE_ID 361
IPV4_ETTA_SALT_IPFIX_TEMPLATE_ID 362
IPV6_ETTA_IDP_TEMPLATE_ID 363
IPV6_ETTA_IDP_IPFIX_TEMPLATE_ID 364
IPV6_ETTA_SPLT_TEMPLATE_ID 365
IPV6_ETTA_SPLT_IPFIX_TEMPLATE_ID 366
IPV6_ETTA_BD_TEMPLATE_ID 367
IPV6_ETTA_BD_IPFIX_TEMPLATE_ID 368
IPV6_ETTA_TLS_TEMPLATE_ID 369
IPV6_ETTA_TLS_IPFIX_TEMPLATE_ID 370
IPV6_ETTA_SALT_TEMPLATE_ID 371
IPV6_ETTA_SALT_IPFIX_TEMPLATE_ID 372
NF_F_IN_BYTES 1
NF_F_IN_PKTS 2
NF_F_PROTOCOL 4
NF_F_SRC_TOS 5
NF_F_TCP_FLAGS 6
NF_F_L4_SRC_PORT 7
NF_F_SRC_ADDR_IPV4 8
NF_F_SRC_INTF_ID 10
NF_F_L4_DST_PORT 11
NF_F_DST_ADDR_IPV4 12
NF_F_DST_INTF_ID 14
NF_F_LAST_SWITCHED 21
NF_F_FIRST_SWITCHED 22
NF_F_SRC_ADDR_IPV6 27
NF_F_DST_ADDR_IPV6 28
NF_F_MIN_TTL 52
NF_F_IN_SRC_MAC 56
NF_F_OUT_DST_MAC 57
NF_F_SRC_VLAN 58
NF_F_MPLS_LABEL_1 70
NF_F_SYSTEM_INIT_TIME_MILLISECONDS 160
NF_F_TCP_SYN_TOTAL_COUNT 218
NF_F_TCP_FIN_TOTAL_COUNT 219
NF_F_TCP_RST_TOTAL_COUNT 220
NF_F_TCP_ACK_TOTAL_COUNT 222
NF_F_IP_SECTION_HEADER 313
NF_F_IP_SECTION_PAYLOAD 314
Note: The Flow Sensor uses Lancope Information Element Identifier Definitions: Private Enterprise Number (PEN) - 8712
More information about these elements is available in the Secure Analytics Information Elements guide
NF_F_FLOWSENSOR_INITIATOR 29794
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT 29795
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT 29796
NF_F_FLOWSENSOR_RTT 29797
NF_F_FLOWSENSOR_SVR_RESP 29798
NF_F_FLOWSENSOR_RETRANSMITS 29799
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT 29800
NF_F_FLOWSENSOR_TCP_FRAG_TOTAL_COUNT 29801
NF_F_FLOWSENSOR_SRC_EMAIL_IN 29802
NF_F_FLOWSENSOR_SRC_EMAIL_OUT 29803
NF_F_FLOWSENSOR_SRC_EMAIL_IN_MESS 29804
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_MESS 29805
NF_F_FLOWSENSOR_SRC_EMAIL_IN_TRYS 29806
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_TRYS 29807
NF_F_FLOWSENSOR_DST_EMAIL_IN 29808
NF_F_FLOWSENSOR_DST_EMAIL_OUT 29809
NF_F_FLOWSENSOR_DST_EMAIL_IN_MESS 29810
NF_F_FLOWSENSOR_DST_EMAIL_OUT_MESS 29811
NF_F_FLOWSENSOR_DST_EMAIL_IN_TRYS 29812
NF_F_FLOWSENSOR_DST_EMAIL_OUT_TRYS 29813
NF_F_FLOWSENSOR_TRACES 29814
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL 29817
NF_F_FLOWSENSOR_EMB_ICMP_TYPE 29818
NF_F_FLOWSENSOR_EMB_ICMP_CODE 29819
NF_F_FLOWSENSOR_APPLICATION_ID 29820
NF_F_FLOWSENSOR_BAD_FLAG_XMAS 29821
NF_F_FLOWSENSOR_BAD_FLAG_SYN_FIN 29822
NF_F_FLOWSENSOR_BAD_FLAG_BAD_RST 29823
NF_F_FLOWSENSOR_BAD_FLAG_NO_ACK 29824
NF_F_FLOWSENSOR_BAD_FLAG_URG 29825
NF_F_FLOWSENSOR_BAD_FLAG_NOFLAG 29826
NF_F_FLOWSENSOR_BAD_TCP_PROBE 29827
NF_F_FLOWSENSOR_SHORT_FRAG_ATTACK 29828
NF_F_FLOWSENSOR_FRAG_PKT_TOO_SHORT 29829
NF_F_FLOWSENSOR_FRAG_PKT_TOO_LONG 29830
NF_F_FLOWSENSOR_FRAG_DIFFERENT_SIZES 29831
NF_F_FLOWSENSOR_APPLICATION_DETAILS 29832
Note: Each template includes the Template Name and field count, followed by the individual NetFlow/IPFIX fields and the size of each field (in bytes).
Note that Enterprise-specific IPFIX elements are ored with 0x8000 to turn on the high bit, so the collector knows that the Private Enterprise Number (PEN) field is present.
An example with NetFlow v9 and Enterprise-specific IPFIX elements is included.
TEMPLATE_NAME, ## <-- Field Count (Total number of NF_F fields in the template)
FIELD_NAME_V9, # <-- Field size (in bytes)
ENTERPRISE_FIELD_NAME_IPFIX | 0x8000, # <-- Field size (in bytes)
0000, 8712 <-- Private Enterprise Number (PEN)
Note: This template is used for the initial v9 export of IPv4 flow information from a flow slot in the Flow Sensor engine.
IPV4_FIRST_FLOW_TEMPLATE_ID, 31
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_FLOWSENSOR_INITIATOR, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for the initial v9 export of IPv4 flow information from a flow slot in the Flow Sensor engine when the Export Packet Payload check box is selected.
IPV4_FIRST_FLOW_DEEP_TEMPLATE_ID, 33
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_IP_SECTION_HEADER, 64
NF_F_IP_SECTION_PAYLOAD, 26
NF_F_FLOWSENSOR_INITIATOR, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for follow-on v9 exports of IPv4 flow information from a flow slot in the Flow Sensor engine.
IPV4_FLOW_TEMPLATE_ID, 25
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_MIN_TTL, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for v9 exports of IPv4 bad fragment and flag combination counts detected by the Flow Sensor engine.
IPV4_EVENT_TEMPLATE_ID, 18
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_PROTOCOL, 1
NF_F_FLOWSENSOR_BAD_FLAG_XMAS, 2
NF_F_FLOWSENSOR_BAD_FLAG_SYN_FIN, 2
NF_F_FLOWSENSOR_BAD_FLAG_BAD_RST, 2
NF_F_FLOWSENSOR_BAD_FLAG_NO_ACK, 2
NF_F_FLOWSENSOR_BAD_FLAG_URG, 2
NF_F_FLOWSENSOR_BAD_FLAG_NOFLAG, 2
NF_F_FLOWSENSOR_BAD_TCP_PROBE, 2
NF_F_FLOWSENSOR_SHORT_FRAG_ATTACK, 2
NF_F_FLOWSENSOR_FRAG_PKT_TOO_SHORT, 2
NF_F_FLOWSENSOR_FRAG_PKT_TOO_LONG, 2
NF_F_FLOWSENSOR_FRAG_DIFFERENT_SIZES, 2
Note: This template is used for the initial v9 export of IPv6 flow information from a flow slot in the Flow Sensor engine.
IPV6_FIRST_FLOW_TEMPLATE_ID, 31
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_FLOWSENSOR_INITIATOR, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for the initial v9 export of IPv6 flow information from a flow slot in the Flow Sensor engine when the Export Packet Payload check box is selected.
IPV6_FIRST_FLOW_DEEP_TEMPLATE_ID, 33
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_IP_SECTION_HEADER, 64
NF_F_IP_SECTION_PAYLOAD, 26
NF_F_FLOWSENSOR_INITIATOR, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for follow-on v9 exports of IPv6 flow information from a flow slot in the Flow Sensor engine.
IPV6_FLOW_TEMPLATE_ID, 25
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_MIN_TTL, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for v9 exports of IPv6 bad fragment and flag combination counts detected by the Flow Sensor engine.
IPV6_EVENT_TEMPLATE_ID, 18
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_PROTOCOL, 1
NF_F_FLOWSENSOR_BAD_FLAG_XMAS, 2
NF_F_FLOWSENSOR_BAD_FLAG_SYN_FIN, 2
NF_F_FLOWSENSOR_BAD_FLAG_BAD_RST, 2
NF_F_FLOWSENSOR_BAD_FLAG_NO_ACK, 2
NF_F_FLOWSENSOR_BAD_FLAG_URG, 2
NF_F_FLOWSENSOR_BAD_FLAG_NOFLAG, 2
NF_F_FLOWSENSOR_BAD_TCP_PROBE, 2
NF_F_FLOWSENSOR_SHORT_FRAG_ATTACK, 2
NF_F_FLOWSENSOR_FRAG_PKT_TOO_SHORT, 2
NF_F_FLOWSENSOR_FRAG_PKT_TOO_LONG, 2
NF_F_FLOWSENSOR_FRAG_DIFFERENT_SIZES, 2
Note: This template is used for v9 exports of IPv4 email counts information sourced from the source IP address as detected by the Flow Sensor engine.
IPV4_SRC_EMAIL_COUNTS_TEMPLATE_ID, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_FLOWSENSOR_SRC_EMAIL_IN, 4
NF_F_FLOWSENSOR_SRC_EMAIL_OUT, 4
NF_F_FLOWSENSOR_SRC_EMAIL_IN_MESS, 4
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_MESS, 4
NF_F_FLOWSENSOR_SRC_EMAIL_IN_TRYS, 4
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_TRYS, 4
Note: This template is used for the initial v9 export of IPv4 flow information from a flow slot in the Flow Sensor engine when RTM data has been computed.
IPV4_FIRST_FLOW_RTM_TEMPLATE_ID, 34
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_FLOWSENSOR_INITIATOR, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_RTT, 4
NF_F_FLOWSENSOR_SVR_RESP, 4
NF_F_FLOWSENSOR_RETRANSMITS, 2
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for the initial v9 export of IPv4 flow information from a flow slot in the Flow Sensor engine when the Export Packet Payload check box is selected and RTM data has been computed.
IPV4_FIRST_FLOW_DEEP_RTM_TEMPLATE_ID, 36
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_IP_SECTION_HEADER, 64
NF_F_IP_SECTION_PAYLOAD, 26
NF_F_FLOWSENSOR_INITIATOR, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_RTT, 4
NF_F_FLOWSENSOR_SVR_RESP, 4
NF_F_FLOWSENSOR_RETRANSMITS, 2
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for follow-on v9 exports of IPv4 flow information from a flow slot in the Flow Sensor engine when RTM data has been computed.
IPV4_FLOW_RTM_TEMPLATE_ID, 28
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_MIN_TTL, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_RTT, 4
NF_F_FLOWSENSOR_SVR_RESP, 4
NF_F_FLOWSENSOR_RETRANSMITS, 2
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for the initial v9 export of IPv6 flow information from a flow slot in the Flow Sensor engine when RTM data has been computed.
IPV6_FIRST_FLOW_RTM_TEMPLATE_ID, 34
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_FLOWSENSOR_INITIATOR, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_RTT, 4
NF_F_FLOWSENSOR_SVR_RESP, 4
NF_F_FLOWSENSOR_RETRANSMITS, 2
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for the initial v9 export of IPv6 flow information from a flow slot in the Flow Sensor engine when the Export Packet Payload check box is selected and RTM data has been computed.
IPV6_FIRST_FLOW_DEEP_RTM_TEMPLATE_ID, 36
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_IP_SECTION_HEADER, 64
NF_F_IP_SECTION_PAYLOAD, 26
NF_F_FLOWSENSOR_INITIATOR, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_RTT, 4
NF_F_FLOWSENSOR_SVR_RESP, 4
NF_F_FLOWSENSOR_RETRANSMITS, 2
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for follow-on v9 exports of IPv6 flow information from a flow slot in the Flow Sensor engine when RTM data has been computed.
IPV6_FLOW_RTM_TEMPLATE_ID, 28
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_MIN_TTL, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TRACES, 2
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL, 1
NF_F_FLOWSENSOR_EMB_ICMP_TYPE, 1
NF_F_FLOWSENSOR_EMB_ICMP_CODE, 1
NF_F_FLOWSENSOR_RTT, 4
NF_F_FLOWSENSOR_SVR_RESP, 4
NF_F_FLOWSENSOR_RETRANSMITS, 2
NF_F_FLOWSENSOR_APPLICATION_ID, 4
Note: This template is used for v9 exports of IPv4 email counts information received by the destination IP address as detected by the Flow Sensor engine.
IPV4_DST_EMAIL_COUNTS_TEMPLATE_ID, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_FLOWSENSOR_DST_EMAIL_IN, 4
NF_F_FLOWSENSOR_DST_EMAIL_OUT, 4
NF_F_FLOWSENSOR_DST_EMAIL_IN_MESS, 4
NF_F_FLOWSENSOR_DST_EMAIL_OUT_MESS, 4
NF_F_FLOWSENSOR_DST_EMAIL_IN_TRYS, 4
NF_F_FLOWSENSOR_DST_EMAIL_OUT_TRYS, 4
Note: This template is used for v9 exports of IPv6 email counts information sourced from the source IP address as detected by the Flow Sensor engine.
IPV6_SRC_EMAIL_COUNTS_TEMPLATE_ID, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_FLOWSENSOR_SRC_EMAIL_IN, 4
NF_F_FLOWSENSOR_SRC_EMAIL_OUT, 4
NF_F_FLOWSENSOR_SRC_EMAIL_IN_MESS, 4
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_MESS, 4
NF_F_FLOWSENSOR_SRC_EMAIL_IN_TRYS, 4
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_TRYS, 4
Note: This template is used for v9 exports of IPv6 email counts information received by the destination IP address as detected by the Flow Sensor engine.
IPV6_DST_EMAIL_COUNTS_TEMPLATE_ID, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_FLOWSENSOR_DST_EMAIL_IN, 4
NF_F_FLOWSENSOR_DST_EMAIL_OUT, 4
NF_F_FLOWSENSOR_DST_EMAIL_IN_MESS, 4
NF_F_FLOWSENSOR_DST_EMAIL_OUT_MESS, 4
NF_F_FLOWSENSOR_DST_EMAIL_IN_TRYS, 4
NF_F_FLOWSENSOR_DST_EMAIL_OUT_TRYS, 4
Note: This template is used for the initial IPFIX export of IPv4 flow information from a flow slot in the Flow Sensor engine.
IPV4_FIRST_FLOW_IPFIX_TEMPLATE_ID, 33
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_FLOWSENSOR_INITIATOR | 0x8000, 1
0000, 8712
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for the initial IPFIX export of IPv4 flow information from a flow slot in the Flow Sensor engine when the Export Packet Payload check box is selected.
IPV4_FIRST_FLOW_DEEP_IPFIX_TEMPLATE_ID, 35
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_IP_SECTION_HEADER, 64
NF_F_IP_SECTION_PAYLOAD, 26
NF_F_FLOWSENSOR_INITIATOR | 0x8000, 1
0000, 8712
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for follow-on IPFIX exports of IPv4 flow information from a flow slot in the Flow Sensor engine.
IPV4_FLOW_IPFIX_TEMPLATE_ID, 27
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_MIN_TTL, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for IPFIX exports of IPv4 bad fragment and flag combination counts detected by the Flow Sensor engine.
IPV4_EVENT_IPFIX_TEMPLATE_ID, 19
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_PROTOCOL, 1
NF_F_FLOWSENSOR_BAD_FLAG_XMAS | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_SYN_FIN | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_BAD_RST | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_NO_ACK | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_URG | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_NOFLAG | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_TCP_PROBE | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_SHORT_FRAG_ATTACK | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_FRAG_PKT_TOO_SHORT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_FRAG_PKT_TOO_LONG | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_FRAG_DIFFERENT_SIZES | 0x8000, 2
0000, 8712
Note: This template is used for the initial IPFIX export of IPv6 flow information from a flow slot in the Flow Sensor engine.
IPV6_FIRST_FLOW_IPFIX_TEMPLATE_ID, 33
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_FLOWSENSOR_INITIATOR | 0x8000, 1
0000, 8712
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for the initial IPFIX export of IPv6 flow information from a flow slot in the Flow Sensor engine when the Export Packet Payload check box is selected.
IPV6_FIRST_FLOW_DEEP_IPFIX_TEMPLATE_ID, 35
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_IP_SECTION_HEADER, 64
NF_F_IP_SECTION_PAYLOAD, 26
NF_F_FLOWSENSOR_INITIATOR | 0x8000, 1
0000, 8712
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for follow-on IPFIX exports of IPv6 flow information from a flow slot in the Flow Sensor engine.
IPV6_FLOW_IPFIX_TEMPLATE_ID, 27
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_MIN_TTL, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for IPFIX exports of IPv6 bad fragment and flag combination counts detected by the Flow Sensor engine.
IPV6_EVENT_IPFIX_TEMPLATE_ID, 19
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_PROTOCOL, 1
NF_F_FLOWSENSOR_BAD_FLAG_XMAS | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_SYN_FIN | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_BAD_RST | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_NO_ACK | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_URG | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_FLAG_NOFLAG | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_BAD_TCP_PROBE | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_SHORT_FRAG_ATTACK | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_FRAG_PKT_TOO_SHORT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_FRAG_PKT_TOO_LONG | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_FRAG_DIFFERENT_SIZES | 0x8000, 2
0000, 8712
Note: This template is used for IPFIX exports of IPv4 email counts information sourced from the source IP address as detected by the Flow Sensor engine.
IPV4_SRC_EMAIL_COUNTS_IPFIX_TEMPLATE_ID, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_FLOWSENSOR_SRC_EMAIL_IN | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_OUT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_IN_MESS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_MESS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_IN_TRYS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_TRYS | 0x8000, 4
0000, 8712
Note: This template is used for the initial IPFIX export of IPv4 flow information from a flow slot in the Flow Sensor engine when RTM data has been computed.
IPV4_FIRST_FLOW_RTM_IPFIX_TEMPLATE_ID, 36
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_FLOWSENSOR_INITIATOR | 0x8000, 1
0000, 8712
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_RTT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SVR_RESP | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_RETRANSMITS | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for the initial IPFIX export of IPv4 flow information from a flow slot in the Flow Sensor engine when the Export Packet Payload check box is selected.
IPV4_FIRST_FLOW_DEEP_RTM_IPFIX_TEMPLATE_ID, 38
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_IP_SECTION_HEADER, 64
NF_F_IP_SECTION_PAYLOAD, 26
NF_F_FLOWSENSOR_INITIATOR | 0x8000, 1
0000, 8712
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_RTT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SVR_RESP | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_RETRANSMITS | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for follow-on IPFIX exports of IPv4 flow information from a flow slot in the Flow Sensor engine when RTM data has been computed.
IPV4_FLOW_RTM_IPFIX_TEMPLATE_ID, 30
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_MIN_TTL, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_RTT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SVR_RESP | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_RETRANSMITS | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for the initial IPFIX export of IPv6 flow information from a flow slot in the Flow Sensor engine when RTM data has been computed.
IPV6_FIRST_FLOW_RTM_IPFIX_TEMPLATE_ID, 36
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_FLOWSENSOR_INITIATOR | 0x8000, 1
0000, 8712
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_RTT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SVR_RESP | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_RETRANSMITS | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for the initial IPFIX export of IPv6 flow information from a flow slot in the Flow Sensor engine when the Export Packet Payload check box is selected.
IPV6_FIRST_FLOW_DEEP_RTM_IPFIX_TEMPLATE_ID, 38
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_SRC_MAC, 6
NF_F_OUT_DST_MAC, 6
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_SRC_VLAN, 2
NF_F_MPLS_LABEL_1, 3
NF_F_MIN_TTL, 1
NF_F_SRC_TOS, 1
NF_F_IP_SECTION_HEADER, 64
NF_F_IP_SECTION_PAYLOAD, 26
NF_F_FLOWSENSOR_INITIATOR | 0x8000, 1
0000, 8712
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_RTT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SVR_RESP | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_RETRANSMITS | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for follow-on IPFIX exports of IPv6 flow information from a flow slot in the Flow Sensor engine when RTM data has been computed.
IPV6_FLOW_RTM_IPFIX_TEMPLATE_ID, 30
NF_F_FIRST_SWITCHED, 4
NF_F_LAST_SWITCHED, 4
NF_F_SYSTEM_INIT_TIME_MILLISECONDS, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_L4_SRC_PORT, 2
NF_F_L4_DST_PORT, 2
NF_F_IN_BYTES, 4
NF_F_IN_PKTS, 4
NF_F_SRC_INTF_ID, 2
NF_F_DST_INTF_ID, 2
NF_F_PROTOCOL, 1
NF_F_TCP_FLAGS, 1
NF_F_MIN_TTL, 1
NF_F_TCP_SYN_TOTAL_COUNT, 2
NF_F_TCP_ACK_TOTAL_COUNT, 2
NF_F_TCP_FIN_TOTAL_COUNT, 2
NF_F_TCP_RST_TOTAL_COUNT, 2
NF_F_FLOWSENSOR_TCP_BAD_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SRS_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TCP_SYN_ACK_TOTAL_COUNT | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_TRACES | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_PROTOCOL | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_TYPE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_EMB_ICMP_CODE | 0x8000, 1
0000, 8712
NF_F_FLOWSENSOR_RTT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SVR_RESP | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_RETRANSMITS | 0x8000, 2
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_ID | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_APPLICATION_DETAILS | 0x8000, 65535
0000, 8712
Note: This template is used for IPFIX exports of IPv4 email counts information received by the destination IP address as detected by the Flow Sensor engine.
IPV4_DST_EMAIL_COUNTS_IPFIX_TEMPLATE_ID, 8
NF_F_SRC_ADDR_IPV4, 4
NF_F_DST_ADDR_IPV4, 4
NF_F_FLOWSENSOR_DST_EMAIL_IN | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_OUT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_IN_MESS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_OUT_MESS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_IN_TRYS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_OUT_TRYS | 0x8000, 4
0000, 8712
Note: This template is used for IPFIX exports of IPv6 email counts information sourced from the source IP address as detected by the Flow Sensor engine.
IPV6_SRC_EMAIL_COUNTS_IPFIX_TEMPLATE_ID, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_FLOWSENSOR_SRC_EMAIL_IN | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_OUT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_IN_MESS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_MESS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_IN_TRYS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_SRC_EMAIL_OUT_TRYS | 0x8000, 4
0000, 8712
Note: This template is used for IPFIX exports of IPv6 email counts information received by the destination IP address as detected by the Flow Sensor engine.
IPV6_DST_EMAIL_COUNTS_IPFIX_TEMPLATE_ID, 8
NF_F_SRC_ADDR_IPV6, 16
NF_F_DST_ADDR_IPV6, 16
NF_F_FLOWSENSOR_DST_EMAIL_IN | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_OUT | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_IN_MESS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_OUT_MESS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_IN_TRYS | 0x8000, 4
0000, 8712
NF_F_FLOWSENSOR_DST_EMAIL_OUT_TRYS | 0x8000, 4
0000, 8712
Note: These templates are used for the sending of ETA data from the Flow Sensor. The contents of these templates was not available for the writing of this article.
Revision | Publish Date | Comments |
---|---|---|
1.0 |
11-Apr-2023 |
Initial Release |