THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Affected Product Name | Description | Comments |
---|---|---|
N3K-C3048TP-1GE | ^^Nexus 3048TP-1GE 1RU 48 x 10/100/1000 and 4 x 10GE ports |
Defect ID | Headline |
CSCvj77373 | Nexus 3048 stuck in reload cycle in rare cases |
Cisco Nexus 3048 Switches might become stuck in a reload cycle when running a Cisco NX-OS Software Release earlier than Release 7.0(3)I7(5).
Cisco Nexus 3048 Switches may become stuck in a reload cycle during upgrade due to an issue with overcurrent protection tolerance, resulting in no console output.
After the Nexus 3048 device is reloaded or power-cycled, it reloads continuously with a flashing blue LED.
There will be no output on the console.
To mitigate this issue, upgrade the power sequencer to firmware version 5.5.
Option 1: Upgrade the power sequencer using a binary script if the device is running a Cisco NX-OS Software 7.0 Release earlier than 7.0(3)I7(5).
switch# configure terminal
switch(config)# feature bash-shell
switch(config)# end
switch# run bash sudo su
root@switch#
root@switch#cd /tmp
root@switch#cp /bootflash/n3048_pwr_seq_v55_i7.bin .
root@switch#
root@switch#chmod +x n3048_pwr_seq_v55_i7.bin
root@switch#
root@switch#./n3048_pwr_seq_v55_i7.bin
Update Seq A
Update Seq B
Power sequencer firmware updated
Option 2: Upgrade to a fixed release of Cisco NXOS Software.
The power sequencer upgrade capability and the packaged power sequencer firmware have been enabled on Cisco NX-OS Software releases 7.0(3)I7(5) and later.
For devices that are running older code, first complete the steps in Option 1, then upgrade to Release 7.0(3)I7(5) or later. Upgrading the power sequencer before upgrading the software is necessary. Otherwise, the NX-OS Software upgrade may cause the device to become stuck in a reload cycle.
If the device is already running NX-OS Software Release 7.0(3)I7(5) or later, perform another installation of the same software image or any later fixed NX-OS image (Example: install all nxos bootflash:nxos.7.0.3.I7.5.bin). This should upgrade the power sequencer firmware.
This field notice only affects N3K-C3048TP-1GE with power sequencer firmware earlier than version 5.5.
For a device that is running NX-OS Software Release 7.0(3)I7(5) or later, use the command in the following example and check the firmware version of the power sequencer in the output:
switch# show install all impact nxos bootflash:n3000-compact.9.3.10.bin
----------SNIP-------
Images will be upgraded according to following table:
Module Image Running-Version(pri:alt) New-Version Upg-Required
------ ---------- ---------------------------------------- -------------------- ------------
1 nxos 9.3(10) 9.3(10) no
1 bios v5.0.0(06/06/2018) v5.0.0(06/06/2018) no
1 power-seq 4.4 5.5 yes
If the output of Running-Version for power-seq is earlier than version 5.5, the device may be affected by the issue described in this field notice and the power sequencer needs to be upgraded.
Version | Description | Section | Date |
1.0 | Initial Release | — | 2024-MAR-08 |
For further assistance or for more information about this field notice, contact the Cisco Technical Assistance Center (TAC) using one of the following methods:
To receive email updates about Field Notices (reliability and safety issues), Security Advisories (network security issues), and end-of-life announcements for specific Cisco products, set up a profile in My Notifications.
Unleash the Power of TAC's Virtual Assistance