THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Revision | Publish Date | Comments |
---|---|---|
1.0 |
30-May-23 |
Initial Release |
Affected Product ID | Comments |
---|---|
NC55-PWR-3KW-AC |
|
NC55-PWR-3KW-AC= |
Part Alternate |
Defect ID | Headline |
---|---|
CSCvz99098 | NCS5500: NC55-PWR-3KW-AC PEM goes to failure on OIR |
The power supply unit (PSU) NC55-PWR-3KW-AC might display error messages, as shown in the Problem Symptom section. The PSU will enter into a failed state with an output disabled alarm during Online Insertion or Removal (OIR) or the installation process.
This issue was identified during the manufacturing test process and necessary changes have been completed in order to address the problem.
This issue does not qualify for a system hardware replacement. There is a software fix available, described in the Workaround/Solution section, to address the problem.
The PSU might show these error messages which help to identify the issue:
show environment power
command shows that the PSU is in the failed or no power state.
sysadmin-vm:0_RP1# show environment power location 0/PM7 DDD MMM DD HH:MM:SS.936 UTC+00:00 0/PM7 3kW-AC 326.1/0.0 /0.0 20.9/0.0 /0.0 10.4 89.1 FAILED or NO PWR
The show alarms
command displays multiple alarms, which includes Power Module Output Disabled
.
sysadmin-vm:0_RP1# show alarms DDD MMM DD HH:MM:SS.936 UTC+00:00 ------------------------------------------------------------------------------- Active Alarms ------------------------------------------------------------------------------- Location Severity Group Set time Description ------------------------------------------------------------------------------- 0/FT2 major environ 10/21/21 10:03:25 Fan tray is removed from chassis. 0/PM7 major environ 10/21/21 11:19:11 Power Module Output Disabled. 0/PM7 major environ 10/21/21 11:19:17 Power Module Fault (LOGIC_CTRL_VOLT_OOR). 0/PM7 major environ 10/21/21 11:19:17 Power Module Fan Fault.
Cisco recommends to install a Software Maintenance Upgrade (SMU) for the respective Cisco IOS® XR release in order to fix the issue. This is also classified as a mandatory SMU for this PSU to be installed now to avoid this issue being seen in future.
Note: If you are on Cisco IOS XR Release 7.8.1 or later you do not need to install this SMU as the fix is already built into the release.
Cisco IOS XR Release | SMU Details | SMU Type |
---|---|---|
Cisco IOS XR Release 7.7.2 | ncs5500-sysadmin-7.7.2.CSCvz99098.tar | Hitless |
Cisco IOS XR Release 7.7.1 | ncs5500-sysadmin-7.7.1.CSCvz99098.tar | Hitless |
Cisco IOS XR Release 7.6.2 | ncs5500-sysadmin-7.6.2.CSCvz99098.tar | Hitless |
Cisco IOS XR Release 7.6.1 | ncs5500-sysadmin-7.6.1.CSCvz99098.tar | Hitless |
Cisco IOS XR Release 7.5.3 | ncs5500-sysadmin-7.5.3.CSCvz99098.tar | Hitless |
Cisco IOS XR Release 7.5.2 | ncs5500-sysadmin-7.5.2.CSCvz99098.tar | Reboot |
Cisco IOS XR Release 7.4.2 | ncs5500-sysadmin-7.4.2.CSCvz99098.tar | Hitless |
Cisco IOS XR Release 7.3.2 | ncs5500-sysadmin-7.3.2.CSCvz99098.tar | Reboot |
Cisco IOS XR Release 7.1.2 | ncs5500-sysadmin-7.1.2.CSCvz99098.tar | Hitless |
Cisco IOS XR Release 7.0.2 | ncs5500-sysadmin-7.0.2.CSCvz99098.tar | Hitless |
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
My Notifications—Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.
Unleash the Power of TAC's Virtual Assistance