THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Revision | Publish Date | Comments |
---|---|---|
1.0
|
12-May-10
|
Initial Release
|
10.0
|
12-Oct-17
|
Migration to new field notice system
|
10.1
|
26-Feb-19
|
Fixed Broken Image Links
|
Affected Product ID | Comments |
---|---|
1OC768-ITU/C
|
|
1OC768-ITU/C=
|
Part Alternate
|
Defect ID | Headline |
---|---|
CSCvf34445 | There were no defects filed with this field notice at the time of publication. |
CRS-1 OC768-ITU/C PLIMs that match the list of affected Serial Number may encounter intermittent burst of High BER events or loss of transmitted optical power after several months of operation. Three different failure mechanisms have been identified in Background section below.
The background for three different failure mechanisms are identified:
Cisco recommends replacing the affected hardware (1OC768-POS-ITU/C). Refer to Figure 2 for TAN number, serial number.
TAN Number | Affected Serial Number Match | Action |
---|---|---|
800-18052-04 | Not applicable | No Action required. Card is updated. |
800-18052-03 | Check serial number, if Affected -> Action | Inspect Inductor L25. If date code is 0628 or older, RMA card |
800-18052-02 | Check Serial number, if Affected -> Action | RMA card |
800-18052-01 | Check Serial number, if Affected -> Action | RMA card |
If your card does not match in above table, no action is required.
Complete these steps in order to check the hardware level of the boards:
RP/0/RP0/CPU0:CRS4A#sh diag 0/3/cpu0 Sun Apr 6 09:24:38.258 PST PLIM 0/3/CPU0 : Cisco CRS-1 OC768 (C-band) DWDM PLIM MAIN: board type 600097 800-18052-01 rev 38<------------- TAN # is here dev 098101<----------------- Deviation # is here S/N SAD103304GK <-----Serial number PCA: 73-7218-02 rev 16 PID: 1OC768-ITU/C VID: V01 CLEI: IPUIAXSRAA ECI: 141603 Board State : IOS XR RUN PLD: Motherboard: 0x0025, Processor: 0xda13, Power: N/A MONLIB: QNXFFS Monlib Version 3.1 ROMMON: Version 1.48(20070928:224557) [CRS-1 ROMMON] Interface port config: 1 Ports Optical reach type: N/A Connector type: N/A
Figure 1: Card View
Figure 2: Card Close-up View
Refer to Figure 3 for inductor location 'A', figure 4 is L25 inductor with date code 0712 is good inductor. Inductor in location B and C shown for reference only in figure 5 and 6 respectively.
Figure 3: Card view - L25 Location
Figure 4: L25 Inductor Location A
Figure 5: Inductor B
Figure 6: Inductor C
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods: